Passive Current Transformers Series IN-D

Differential current transformer Description The residual current transformer makes it possible to measure the residual current on single-phase or three-phase supply cables or individual lines. Both current-carrying conductors (forward and return conductors) are fed through the current opening of the current transformer. The current is measured by comparing the forward and return conductors. Any deviation is displayed at the output of the residual current transformer. Due to the use of highly permeable materials, a typical current deviation from 10 mA is given. The large opening allows the supply lines to pass directly through over a wide area, with the exception of the protective conductor. Due to the high current sensitivity, evaluation in several stages is possible: stage 1: Notice of a malfunction stage 2: Alarm stage 3: Switching off Benefits The measurement from 25 to 400 Hz Nanocrystalline core Transformer for measuring differential current High-quality UL-listed insulating materials (e.g. UL94-V0) Safe electrically isolated primary and secondary circuits Robust housing designs (for horizontal/vertical mounting) Variable connections Wide range of housings with various push-through openings Residual current range 2 – 50 A Typical applications Industry, Renewable energy sources, Metrology and testing techniquesEnergy, automation and building technology Technical data Type 2 4 8 29 30 40 30 40 50 Housing A Housing B Housing C Primary rated current [A] IPN 0,1 – 1 0,1 – 2 0,1 – 4 0,1 – 10 0,1 – 10 0,1 – 10 0,1 – 10 0,1 – 10 0,1 – 10 Max. Primary rated current [A] ImaxPN 2 4 8 20 30 40 30 40 50 Therm. Short-term current ITK 0,5 0,5 0,5 3,6 3,6 3,6 9 9 9 Secondary current [mA] IaN 2 4 4 20 10 5 20 16,67 10 Power [VA] Psek 0,004 0,008 0,016 0,030 0,030 0,015 0,06 0,05 0,06 Ratio KN 500 500 1000 500 1000 2000 500 600 1000 Load resistance [Ω] RB 1000 500 1000 75 300 600 150 180 600 Load voltage [V] URB 2,0 2,0 4,0 1,5 3,0 3,0 3,0 3,0 6,0 Measuring accuracy 50 Hz [%] FU ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 Ambient temperature [°C] TA -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 Frequency range [Hz] f 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 Insulation test voltagePrimary / Secondary /2 sec [kVac] VP 3 3 3 3 3 3 3 3 3 Connection A Flat 6.3 x 0.8 / plug-in connectionMKS 1853 / terminal 1.5 mm² Storage temperature TS -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 Coil resistance RS 11 11 46 4,5 19 65 5,5 6,5 21 Weight m 0,068 0,068 0,070 0,278 0,278 0,290 0,280 0,280 0,290 Standards EN/IEC 61869-1/2 tracking resistance CTI Housing / cast resin 550/660M or 400/600M Creepage distance dCp 18 18 18 8 8 8 18 18 18 Air distance dCI 16 16 16 7 7 7 16 16 16 Dimensions in MM Type Housing PIN connection [mm²] h [mm] b1/b2 [mm] t [mm] DL/DL1 [mm] FS [mm] p/s [mm] a [mm] c [mm] f [mm] e [mm] l [mm] IN-D / 2 A 1 – 2 38 38/54 20 13 / – 6,3 x 0,8 – 30 47 4,8 – 9 IN-D / 4 A 1 – 2 38 38/54 20 13 / – 6,3 x 0,8 – 30 47 4,8 – 9 IN-D / 8 A 1 – 2 38 38/54 20 13 / – 6,3 x 0,8 – 30 47 4,8 – 9 IN-D / 20 B MKS1853 55 50/68 26 20,2 / – – 45 / 45 60 13 4,3 6 x 4,0 23 IN-D / 30 B MKS1853 55 50/68 26 20,2 / – – 45 / 45 60 13 4,3 6 x 4,0 23 IN-D / 40 B MKS1853 55 50/68 26 20,2 / – – 45 / 45 60 13 4,3 6 x 4,0 23 IN-D / 30 C Clamp 83 100/70 28 35 / 38 – 86 / – 14 – 7 – – IN-D / 40 C Clamp 83 100/70 28 35 / 38 – 86 / – 14 – 7 – – IN-D / 30 C Clamp 83 100/70 28 35 / 38 – 86 / – 14 – 7 – – Data sheet All data and configurations can be found in our product data sheet. Download data sheet Certifications

PASSIVE CURRENT TRANSFORMER SERIES IB

Current transformers for PCB mounting Description REO current transformers of the IB series are particularly well suited for mounting on printed circuit boards in the electronics sector of modern drive technology for control purposes and measured value acquisition. Benefits small space requirement PCB mounting according to UL 94 V0 Accuracy class 1 Measurement in the frequency range 50-400Hz low phase error for power measurement very low magnetic reversal and eddy current losses electrically isolated primary and secondary circuits easy-to-install designs Technical data Type IB 0,5/5 IB 0,5/20 IB 0,5/40 Primary current [A] IPN 0 – 5 0 – 20 0 – 40 Max. primary current [A] ImaxPN 7 25 50 Secondary current [mA] IaN 0 – 10 0 – 25 0 – 40 Power [VA] Psek 0 – 0,010 0 – 0,025 0 – 0,040 Translation ratio KN 1:500 1:800 1:1000 Burden resistance [Ω] RB 100 40 25 Burden voltage [V] URB 0 – 1 Measuring accuracy 50 Hz [%] FU ≤ 1 Ambient temperature [°C] TA 0..+85 Frequency range [Hz] f 50 – 400 Insulation test voltage [kVac] VP 3 Dimensions in MM Type Primary current [A] Height [mm] Width [mm] Depth [mm] Opening [mm] PIN thickness [mm] PIN length [mm] IB 05/5 0 – 5 30 26,5/17,5 14,5 10,5 0,7×0,7 5,0 IB 05/20 0 – 20 30 26,5/17,5 14,5 10,5 0,7×0,7 5,0 IB 05/40 0 – 40 30 26,5/17,5 14,5 10,5 0,7×0,7 5,0 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Certifications

ACTIVE CURRENT TRANSFORMER WDI SERIES

AC/DC Direct-Imaging Current Transformers (Open-Loop Converters) Description Direct-imaging current transformer (Open-Loop Converter) The WDI current sensor is a direct-imaging current transformer designed for measuring DC and AC currents. The primary current flow generates a magnetic flux, which is evaluated in the air gap by means of a magnetic circuit and Hall sensor. An electronic circuit processes the signal from the Hall sensor and outputs an exact image of the primary current with a voltage at the output. Advantages (Electrical) Measurement of DC and AC currents Voltage output low power consumption no additional losses in the measuring circuit high-quality insulation materials listed according to UL safe, electrically isolated primary and secondary circuits good value for money Advantages (Mechanical) low weight robust housing designs (horizontal/vertical mounting) Connections: terminals, plugs, flat connectors or cables versatile range of housings with different push-through openings Typical applications Industry, renewable energies, railway technology, energy, automation and building technology Technical data Type 25 150 300 Primary current [A] ÎPN Peak 25 150 300 Max. Primary current [A] ÎmaxPN Peak 0- ± 30 0- ± 180 0- ± 360 Secondary current [mA] ÎoutPN ± 5 ± 5 ± 5 Min. load resistance RBmin ± 15 Vdc ± 30A peak=2 ± 150 peak=2 ± 300 peak=2 ± 180A peak=2 ± 360A peak=2 Max. load resistance RBmax ± 15 Vdc ± 30A peak=10 ± 150 peak=2 ± 300 peak=2 ± 180A peak=2 ± 360A peak=2 Max. peak output voltage [V] ÜaN Peak ± 10 ± 10 ± 10 Operating voltage [Vdc] US ± 5% ± 15 ± 15 ± 15 No-load current [mA] IBO (@ ± 15 V) + loutpN 9 9 9 Insulation test voltage [kV] VP r.m.s. 50 Hz 3 3 3 Impulse withstand voltage[kV] VW 1,2/50μs 3 5 5 Measuring accuracy 50 Hz [%] FU @IPN, TA=25°C ± 0.6 ± 0.6 ± 0.6 Linearity error [%] FLU @TA=25°C ≤ 1.0 ≤ 1.0 ≤ 1.0 Offset voltage [mV] Uo @IPN = 0, TA = 25°C 20 20 20 Drift offset voltage [mV] △Uo Io -25°C…+70°C 60 60 60 Temperature drift [%K] %/△T ≤ 0.05 ≤ 0.05 ≤ 0.05 Response time [μs] tr @ 90% of IPN 25 25 25 Frequency range [kHz] f (-3 dB) DC … 10 (-3 dB) DC … 10 (-3 dB) DC … 10 Ambient temperature [°C] TA -25 to + 75 -25 to + 75 -25 to + 75 Storage temperature[°C] Ts -10 to + 85 -10 to + 85 -10 to + 85 Weight [kg] m 0,075 0,075 0,075 Creepage distance [mm] dCp 4 10 10 Clearance [mm] dCpi 3 9 9 DIMENSIONS IN MM Type PIN connection / 4-pin h [mm] b [mm] b1/b2 [mm] t [mm] DL [mm] p/s [mm] a/a1 [mm] c1/c2 [mm] f [mm] e [mm] l [mm] WDI 25 A; O,-U; +U 39 39 – 26,5 10 – 3 x 10/6,5 25/6,5 M4 – 9 WDI 150 A; O,-U; +U 55 – 55/68 26 20,2 45/45 60/– 13/– 4,3 6,0 x 4,0 23 WDI 300 A; O,-U; +U 55 – 55/68 26 20,2 45/45 60/– 13/– 4,3 6,0 x 4,0 23 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Certifications