Programmable Phase Angle Controller REOVIB MTS 442

IP 20, single-channel control Description The REOVIB MTS series includes single, dual, and triple-channel control units for vibratory feeder drives. These are phase-angle controls. Consequently, the vibration frequency of the conveying devices can be equal to or twice as high as the mains frequency of the input voltage (depending on the type, other frequencies are also possible). Plug connections for all inputs and outputs enable quick connection and facilitate the combination of multiple devices with each other or with external controls. The devices operate with digital technology and are operated via an LED or LCD display and buttons. All settings can be made without the housing having to be opened. REOVIB MTS 441 control devices have a target value setting for conveying speed. The REOVIB MTS 442 has two power outputs and the REOVIB MTS 443 has 3 power outputs, that can be linked according to the the application requirements (e.g. bowl and linear conveyors). Also Various sensor and valve logic can be programmed. All parameters of REOVIB MTS 441, 442 und 443 can be input via a display integrated into the faceplate. The devices can be used to link additional devices from the REOVIB MTS series. Application-specific settings can be stored and retrieved when required. The devices of REOVIB MTS 441 and 620 are available in protection class IP20. Additionally the REOVIB MTS 441 is just as the REOVIB MTS 442 and 443 available in a standalone IP54 housing with various connection options: Input cable/output socket Complete cable connection solution for mains, output and control connections Benefits Phase-angle control with programmable functions Single-channel, two-channel or three-channel control for the optimal control of the complete conveyor system Digital setting of all parameters via LED display or multiline LCD display (MTS 443 LCD) In IP54 or IP20 design (MTS 441) Automatic mains voltage adjustment Material flow control Various sensor logic functions can be set Adjustable soft start With fill level/overflow control Integrated mains voltage compensation with constant vibration amplitude Technical data Mains input 110/230 V automatic detection Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V Output current per output max. 6A Number of outputs 2 Max. output current of all outputs 10 A Vibration frequency 50/ 100 Hz (60/120 Hz) Setpoint specification Display Status signal 24 V DC Ext. enable 24 V DC, switch Sensor supply 24 V DC Setting Umin/ Umax Display Soft start Adjustable 0…5 Sec. Full level control / congestion control each output PNP, 24 V DC Mains voltage compensation ✓ Coarse-/fine control ✓ Selectable cycle operation ✓ Sensor time out control ✓ Conformity CE, RoHS Protection class IP54 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Zertifizierung

Programmable Phase Angle Controller REOVIB MTS 441

IP54 or IP20 Description The REOVIB MTS series includes single, dual, and triple-channel control units for vibratory feeder drives. These are phase-angle controls. Consequently, the vibration frequency of the conveying devices can be equal to or twice as high as the mains frequency of the input voltage (depending on the type, other frequencies are also possible). Plug connections for all inputs and outputs enable quick connection and facilitate the combination of multiple devices with each other or with external controls. The devices operate using digital technology and are controlled via an LED or LCD display and buttons. All settings can be made without the housing having to be opened. The REOVIB MTS 441 control units have a setpoint adjustment option for the conveying speed. All parameters can be entered via the display integrated in the front panel. The MTS 441 can be linked to other devices from the REOVIB MTS series. User-specific settings can be saved and recalled. The REOVIB MTS 441 is available in IP20 and IP54 versions, as well as in various connection variants: Input cable/output socket Complete cable connection solution for mains, output and control connections Benefits Phase-angle control with programmable functions Single-channel, two-channel or three-channel control for the optimal control of the complete conveyor system Digital setting of all parameters via LED display or multiline LCD display (MTS 443 LCD) In IP54 or IP20 design (MTS 441) Automatic mains voltage adjustment Material flow control Various sensor logic functions can be set Adjustable soft start With fill level/overflow control Integrated mains voltage compensation with constant vibration amplitude Technical data Mains input 110/230 V automatic detection Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V Output current max. 6 A, max. 10 A (Option) Number of outputs 1 Max. output current of all outputs – Vibration frequency 50 … 100 Hz (60/120 Hz) Setpoint value Display, P0ti, 0 … 10 V, 0 (4) … 20 mA Status signal 24 V DC Ext. enable 24 V DC, switch Sensor supply 24 V DC Setting Umin/ Umax Display Soft start Adjustable 0…5 Sec. Fill level/ overflow control PNP, 24 V DC Mains voltage compensation ✓ Coarse-/fine control ✓ Selectable cycle operation ✓ Sensor time out control ✓ Conformity CE, RoHS Protection class IP20/ IP54 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Zertifizierung

Phase angle control REOVIB RTS SYSTEM

IP00, switch cabinet mounting Description Basic module RTS SYSTEM In open design for mounting on a DIN rail with an output channel of max. 6 A with fill level control/level switch and mains voltage compensation. The basic module has a power supply for expansion modules. This means that additional output modules can be added up to a total current of 10 A. RTS SYSTEM extension module In open design for mounting on a DIN rail. The extension module has one output channel max. 6 A with fill level control/backlog circuit and mains voltage compensation, and can be set up together with the basic module and several expansion modules. REOVIB RTS SINGLE In open design for mounting on a DIN rail with an output channel of max. 6 A, level control/level switch and mains voltage compensation. Benefits Cost-effective Phase-Angle Controls with IP00 protection class for control cabinet mounting can be used as a stand-alone device or modular version for multiple outputs Output current up to 6 A Versions available with fill level/overflow control Mains voltage compensation with constant amplitude Adjustable soft start ramp time Typical applications Conveyor & assembly automation, conveyor technology, sieving technology Technical data RTS Single RTS basic module RTS extension module Mains input 110/ 230V switchable 110/ 230V switchable via RTS basic module Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz via RTS basic module Output voltage 20 … 100V/40…210 V 20 … 100V/40…210 V 20 … 100V/40…210 V Output current max. 6 A max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) Setpoint specification P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA Ext. enable 24 V DC, switch 24 V DC, switch 24 V DC, switch Umin/ Umax internal potentiometers internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. adjustable 0.2…5 sec. Max. output current of all outputs – 10 A – Mains voltage compensation ✓ ✓ ✓ Fill level control/ congestion control ✓ ✓ ✓ Conformity CE, RoHS CE, RoHS CE, RoHS Protection class IP00 IP00 IP00 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Zertifizierung

Phase Angle Controller REOVIB RTS RS6/539

IP54 design for mounting directly on the vibrating machine, single output Description The devices in the REOVIB RTS series are available as a housing variant with protection class IP54 for direct installation on the system. The maximum output current is 6 A. The devices have a compensation circuit for constant oscillation amplitude in the event of mains voltage fluctuations, potentiometers for setting the Umin / Umax and the soft start time as well as a level control/back-up circuit. (Devices with level control/back-up circuit contain a back-up relay for linking with other control devices). The control units are available in different versions: Input cable/output cable Input cable/output socket Complete cable connection solution for mains, output and control connections(For REOVIB RTS RS6/539-559). Benefits Versions available with fill level/overflow control cost-effective Phase-Angle Controls with advanced functionalities IP54 design for mounting directly on the vibrating machine Output current up to 6 A Mains voltage compensation with constant amplitude Adjustable soft start ramp time Typical applications Conveyor & assembly automation, conveyor technology, sieving technology Technical data RTS R6/539 RTS RS6/539-559 Mains input 110/ 230 V switchable 110/ 230 V switchable Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V 20 … 100V/ 40…210 V Output current max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120 Hz) 50 … 100 Hz(60/120 Hz) Setpoint specification Potentiometer, 0 … 10 V, 0 … 20 mA Potentiometer, 0 … 10 V, 0 … 20 mA Ext. enable 24 V DC, switch 24 V DC, switch Umin/ Umax internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. Status relay optional ✓ Mains voltage compensation ✓ ✓ Fill level control/ congestion control – ✓ Conformity CE, RoHS CE, RoHS Protection class IP54 IP54 *For IP54 Data sheet You can find all data and configurations in our product data sheet. Download data sheet Zertifizierung

Phase Angle Controller REOVIB RTS R6/539

IP54 design for mounting directly on the vibrating machine, single output Description The devices in the REOVIB RTS series are available as a housing variant with protection class IP54 for direct installation on the system. The maximum output current is 6 A. The devices have a compensation circuit for constant amplitude in the event of mains voltage fluctuations, potentiometers for setting Umin / Umax and the soft start time. (Devices with fill level control / back-up circuit include a back-up relay for linking to other control devices). The control units are available in different versions: Input cable/output cable Input cable/output socket Benefits cost-effective Phase-Angle Controls with enhanced functionalities IP54 design for mounting directly on the vibrating machine Output current up to 6 A Versions with level control / accumulation circuit available (REOVIB RTS RS6/539-559) Mains voltage compensation with constant amplitude Adjustable soft start ramp time Typical applications Conveyor & assembly automation, conveyor technology, sieving technology Technical data Mains input 110/ 230 V switchable 110/ 230 V switchable Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/40…210 V 20 … 100V/40…210 V Output current max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) Setpoint specification P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA Ext. enable 24 V DC, switch 24 V DC, switch Umin/ Umax setting Internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. Status relay optional ✓ Mains voltage compensation ✓ ✓ Fill level control/ congestion control – ✓ Conformity CE, RoHS CE, RoHS Protection class IP54 IP54 *For IP54 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Zertifizierung />

AC Magnet REOVIB WI 111

IP 00, for DIN rail mounting Description Standard series, fully encapsulated, maximum power of 350 VA at 3000 1/min or 6000 1/min Mounting by means of standard round holes, base plate or slotted holes Cable exit downwards or sideways Benefits Optimum size/performance ratio Good adjustability Safe mounting by means of solid base plate/mountings through the core Compact and robust structure TYPICAL APPLICATIONS Packaging industry and weighing sector for feeding and sorting processesAutomation process and assembly equipment which utilises electromagnetic drives. Technical data Types Max. Nominal air gap [mm] Power at 3000 1/min [VA] Rated current = thermal rated current at 230 V [N] Peak tractive force at nominal air gap [N] Weight [kg] 6000 1/min [VA] Magnet Anchor REOVIB WI 111/3 2 15 0,065 5 0,135 0,025 REOVIB WI 111/5 1 60 0,26 38 0,405 0,085 REOVIB WI 111/6 2,5 70 0,3 24 0,58 0,11 REOVIB WI 111/7 3 140 0,6 45 1,15 0,165 REOVIB WI 111/9 3 350 1,5 150 1,98 0,33 Technical Dimensions Types a b c d e f1 f2 f3 g h i k l [mm] l1 m ⌀n ⌀o p ⌀r s [mm] ⌀t REVIB WI 111/3 44,4 26,4 30 32 2 42 9 5 30 12 10 4,2 22 20 22 4,2 4,4 – 4,4 20 3,6 REVIB WI 111/5 61,5 31,5 45 50 3 63 14 7,5 45 16 15 3 43 35 36 4,2 4,4 15 5,1 28 5,1 REVIB WI 111/6 64 42 45 50 3 63 14 7,5 45 20,5 15 – 43 35 36 4,2 4,4 15 5,1 28 5,1 REVIB WI 111/7 78 47 54 60 3 77 17 10 54 21 20 4,5 45 40 45 7 5,5 20 6,5 37 6,5 REVIB WI 111/9 90 56 66 83 3 88 19 11 66 32,5 22 – 66 50 66 7 6,4 44 8,1 44 8,1 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Certifications

AC Magnet REOVIB WE 131

Packaging and weighing industry for feeding and sorting processes; automation processes when using drives with vibrating magnets.