EMC Filter N CNW 105

Three-phase line filters (4 lines, single stage) (3A – 150A) Description NEW SERIES! The new series not only scores points for its faster delivery time, but also for its resource conservation and increased efficiency. Recommended filter for interference suppression according to EN 55011, Class A and EN 61800-3, Category C2. By using a REO three-phase line filter CNW 105 the noise level is reduced below the prescribed maximum value.REO line filters are suitable for individual and collective suppression. For collective suppression: As long as the rated current for each phase remains below the permissible extent, multiple devices can be suppressed. Benefits small dimensions Quick connection low-temperature rise touch-proof terminals good damping performance ata low leakage current Typical applications Power supply units for data systems engineering, telecommunications, medical equipment and industrial applications Technical data According to: IEC/EN 60939 / IEC 950 / UL 1283 Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s Overload: 1.5 x I 1 min/h Climate category: DIN IEC 68 Part 1 25/085/21 Type Rated voltage [V] Rated current [A] Operating Current [mA] Cx [μF] Cy nF] L [mH] R [MOhm] Frequency [Hz] N CNW 105/3 3×500 4×3 <1 0,5 30 4,0 1,12 50/60 N CNW 105/6 3×500 4×6 <1 0,5 30 2,4 1,12 50/60 N CNW 105/10 3×500 4×10 <1 0,5 30 1,0 1,12 50/60 N CNW 105/16 3×500 4×16 <1 1 43 1,6 1,12 50/60 N CNW 105/25 3×500 4×25 <1 1 43 1,4 1,12 50/60 N CNW 105/36 3×500 4×36 <1 2,2 44 1,2 1,12 50/60 N CNW 105/50 3×500 4×50 <1 2,2 44 0,75 1,12 50/60 N CNW 105/80 3×500 4×80 <3,5 3,3 111 0,5 1,12 50/60 N CNW 101/120 3×500 4×120 <3,5 3,3 111 0,36 1,12 50/60 CNW 105/150 3×500 4×150 <3,5 3,3 111 0,36 1,12 50/60 Dimensions in mm Type Housing Connection PE-Connection B1[mm] B2[mm] B2[mm] D[mm] H[mm] L1[mm] L2[mm] L3[mm] CNW 105/3 A Flat plug 6,3 mm AMP flat plug 53 – – 5,3 40 110 100 90 CNW 105/6 A Flat plug 6,3 mm AMP flat plug 53 – – 5,3 40 110 100 90 CNW 105/10 A Flat plug 6,3 mm AMP flat plug 53 – – 5,3 40 110 100 90 CNW 105/16 B Clamps 4mm² Earthing bolt (M6) 98 80 70 5,0 70 177 150 90 CNW 105/25 B Clamps 6mm² Earthing bolt (M6) 98 80 70 5,0 70 179 150 90 CNW 105/36 B Clamps10mm² Earthing bolt (M6) 148 135 120 7,0 70 269 240 160 CNW 105/50 B Clamps 25mm² Earthing bolt (M6) 148 135 120 7,0 70 278 240 160 CNW 105/80 B Clamps 25mm² Earthing bolt (M10) 168 155 140 7,0 90 303 240 160 CNW 105/120 B Clamps 50mm² Earthing bolt (M12) 168 155 140 7,0 90 331 240 160 CNW 105/150 B Clamps 50mm² Earthing bolt (M12) 168 155 140 7,0 90 331 240 160 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Certifications
EMC Filter N CNW 103

Three-phase line filters (3 lines, single-stage) Description NEW SERIES! The new series not only scores points for its faster delivery time, but also for its resource conservation and increased efficiency. Recommended filter for suppressing interference according to EN 55011, Class A and EN 61800-3, category C2. Special installation Special connections For space and for assembly reasons it may be reasonable to use connections other than terminals. If the filter is always fitted in the same place, REO can build your individual filter-whether with bolts, cable or other connections. Benefits small dimensions Quick connection low-temperature rise touch-proof terminals good damping performance ata low leakage current useable for industrial applications Typical Applications Frequency converters for motor drives, e.g., elevators, conveyor technology, pumps, ventilation and air conditioning, industrial applications, wind turbines, and power supplies Technical Data According to: IEC/EN 60939 / IEC 950 / UL 1283 Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s Overload: 1.5 x I 1 min/h Climate category: DIN IEC 68 Part 1 25/085/21 Type Rated voltage [V] Rated current [A] Operating Current [mA] Cx [μF] Cy [nF] L [mH] R [kOhm] Frequency [Hz] CNW 103/3 3×500 3×3 <1 0,5 30 3,0 1,12 50/60 Hz CNW 103/6 3×500 3×6 <1 0,5 30 2,2 1,12 50/60 Hz CNW 103/10 3×500 3×10 <1 0,5 30 1,7 1,12 50/60 Hz N CNW 103/16 3×500 3×16 <<1 1,0 39 1,5 1,12 50/60 Hz N CNW 103/25 3×500 3×25 <1 1,0 39 1,2 1,12 50/60 Hz N CNW 103/36 3×500 3×36 <1,5 2,2 60 1,5 1,12 50/60 Hz N CNW 103/50 3×500 3×50 <1,5 2,2 60 0,9 1,12 50/60 Hz N CNW 103/80 3×500 3×80 <5 2,75 197 0,4 1,12 50/60 Hz N CNW 103/120 3×500 3×120 <5 2,75 197 0,25 1,12 50/60 Hz N CNW 103/150 3×500 3×150 <5 2,75 197 0,8 1,12 50/60 Hz N CNW 103/180 3×500 3×180 <5 2,75 197 0,8 1,12 50/60 Hz Dimensions in mm Type Housing Connection PE-Connection B1[mm] B2[mm] B2[mm] D[mm] H[mm] L1[mm] L2[mm] L3[mm] CNW 103/3 A Flat plug 6,3 mm AMP flat plug 53 – – 5,3 40 110 100 90 CNW 103/6 A Flat plug 6,3 mm AMP flat plug 53 – – 5,3 40 110 100 90 CNW 103/10 A Flat plug 6,3 mm AMP flat plug 53 – – 5,3 40 110 100 90 N CNW 103/16 B Clamps 4mm² Earthing bolt (M6) 98 80 70 5,0 70 177 150 90 N CNW 103/25 B Clamps 6mm² Earthing bolt (M6) 98 80 70 5,0 70 179 150 90 N CNW 103/36 B Clamps10mm² Earthing bolt (M6) 148 135 120 7,0 70 229 200 160 N CNW 103/50 B Clamps16mm² Earthing bolt (M6) 148 135 120 7,0 70 238 200 160 N CNW 103/80 B Clamps 25mm² Earthing bolt (M10) 168 155 140 7,0 90 303 240 160 N CNW 103/120 B Clamps 50mm² Earthing bolt (M12) 168 155 140 7,0 90 331 240 160 N CNW 103/150 B Clamps 50mm² Earthing bolt (M12) 168 155 140 7,0 90 331 240 160 N CNW 103/180 B Clamps 95mm² Earthing bolt (M12) 168 155 140 7,0 90 339 240 160 Datasheet All data and configurations can be found in our product datasheet. Download Datasheet Certifications
EMC Filter CNW 102

Single-phase line filter (2 conductors, two-stage) Description Recommended filter for interference suppression according to EN 55011, Class B and EN 61800-3, Category C1. Cost-effective filter that is well-suited for direct mounting in the housing of an interference source due to its small dimensions and very good attenuation values in a two-stage design. The filter is also available as a version with low leakage current as well as a special medical version (without Y-capacitors). Optionally, the filter can also be supplied with overvoltage protection. A quick installation can be performed using connection with insulated flat connectors. However, versions with other connection options (terminal / wire) are also possible. Benefits small dimensions Quick connection touch-proof if used with insulated spade connectors very good damping performance at a low leakage current also as a medical version or with a lower leakage current available optional anti-surge protection UL approval for the complete model range – E217177 (not for N- and MED-versions) Typical applications Switched-mode power supplies in industrial electronics, frequency converters for motor drives, power supplies, medical and telecommunications technology, DC applications Technical data According to: IEC/EN 60939 / IEC 950 / UL 1283 Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s Overload: 1.5 x I 1 min/h Climate category: DIN IEC 68 Part 1 25/085/21 Type Rated voltage [V] Rated current [A] Operating Current [mA] Cx [μF] Cy nF] L [mH] R [kOhm] CNW 102/3 250 3 <3,5 0,94 20 13,6 560 CNW 102/6 250 6 <3,5 0,94 20 7,8 560 CNW 102/10 250 10 <3,5 0,94 20 3,6 560 CNW 102/16 250 16 <3,5 0,94 20 2,4 560 CNW 102/20 250 20 <3,5 0,94 20 2,0 560 CNW 102/3/N 250 3 <0,5 0,94 4,4 13,6 560 CNW 102/6/N 250 6 <0,5 0,94 4,4 7,8 560 CNW 102/10/N 250 10 <0,5 0,94 4,4 3,6 560 CNW 1022/16/N 250 16 <0,5 0,94 4,4 2,4 560 CNW 102/20/N 250 20 <0,5 0,94 4,4 2,0 560 CNW 102/3/MED 250 3 <0,005 0,94 – 13,6 560 CNW 102/6/MED 250 6 <0,005 0,94 – 7,8 560 CNW 102/10/MED 250 10 <0,005 0,94 – 3,6 560 CNW 102/16/MED 250 16 <0,005 0,94 – 2,4 560 CNW 102/20/MED 250 20 <0,005 0,94 – 2,0 560 Dimensions in mm Type Connection /PE-Connection B [mm] D [mm] H [mm] L1 [mm] L2[mm] L3[kOhm] CNW 102/3 Flat plug 6,3×0,8 50 5,3 40 87 75 65 CNW 102/6 Flat plug 6,3×0,8 50 5,3 40 87 75 65 CNW 102/10 Flat plug 6,3×0,8 50 5,3 40 87 75 65 CNW 102/16 Flat plug 6,3×0,8 53 5,3 40 110 100 90 CNW 102/20 Flat plug 6,3×0,8 53 5,3 40 110 100 90 Datasheet All data and configurations can be found in our product datasheet. Download Datasheet Certifications