REO Resistance Load
Features
- 7 fixed resistance levels and a fine adjustment level
- Push buttons and switches Ø 22 mm for operation
- Built-in forced cooling and digital interface for external PLC operation with 24 V, DC relays
- Individual resistance levels can be switched on or off via contactors.
Benefits
- Operation of the unit locally or via a PLC is possible
- Fine adjustment via motor-driven ring potentiometer possible locally or via PLC
- Additional 24 V DC available for PLC operation
- Mobile design and connection option via connectors or laboratory sockets
Typical Applications
These load units are used for continuous operation and serve for continuous testing of converters and switched-mode power supplies for railway operation.
Technical Data
Voltage | 230 V 50 / 60 Hz |
Resistance Values | 1 – 10,000 Ohm |
Current | 0.1 – 250 A |
Resistance Accuracy | +/- 5% |
Protection Class | IP 20 |
All data and configurations can be found in our product datasheet.