IP 20, single-channel control
Description
The REOVIB MTS series includes single, dual, and triple-channel control units for vibratory feeder drives. These are phase-angle controls. Consequently, the vibration frequency of the conveying devices can be equal to or twice as high as the mains frequency of the input voltage (depending on the type, other frequencies are also possible). Plug connections for all inputs and outputs enable quick connection and facilitate the combination of multiple devices with each other or with external controls. The devices operate with digital technology and are operated via an LED or LCD display and buttons. All settings can be made without the housing having to be opened.
REOVIB MTS 441 control devices have a target value setting for conveying speed. The REOVIB MTS 442 has two power outputs and the REOVIB MTS 443 has 3 power outputs, that can be linked according to the the application requirements (e.g. bowl and linear conveyors). Also Various sensor and valve logic can be programmed.
All parameters of REOVIB MTS 441, 442 und 443 can be input via a display integrated into the faceplate. The devices can be used to link additional devices from the REOVIB MTS series. Application-specific settings can be stored and retrieved when required.
The devices of REOVIB MTS 441 and 620 are available in protection class IP20. Additionally the REOVIB MTS 441 is just as the REOVIB MTS 442 and 443 available in a standalone IP54 housing with various connection options:
- Input cable/output socket
- Complete cable connection solution for mains, output and control connections
Benefits
- Phase-angle control with programmable functions
- Single-channel, two-channel or three-channel control for the optimal control of the complete conveyor system
- Digital setting of all parameters via LED display or multiline LCD display (MTS 443 LCD)
- In IP54 or IP20 design (MTS 441)
- Automatic mains voltage adjustment
- Material flow control
- Various sensor logic functions can be set
- Adjustable soft start
- With fill level/overflow control
- Integrated mains voltage compensation with constant vibration amplitude
Mains input | 110/230 V automatic detection |
Mains frequency | 50 / 60 Hz +/- 3 Hz |
Output voltage | 20 … 100V/ 40…210 V |
Output current | per output max. 6A |
Number of outputs | 2 |
Max. output current of all outputs | 10 A |
Vibration frequency | 50/ 100 Hz (60/120 Hz) |
Setpoint specification | Display |
Status signal | 24 V DC |
Ext. enable | 24 V DC, switch |
Sensor supply | 24 V DC |
Setting Umin/ Umax | Display |
Soft start | Adjustable 0…5 Sec. |
Full level control / congestion control | each output PNP, 24 V DC |
Mains voltage compensation | ✓ |
Coarse-/fine control | ✓ |
Selectable cycle operation | ✓ |
Sensor time out control | ✓ |
Conformity | CE, RoHS |
Protection class | IP54 |
All data and configurations can be found in our product data sheet.