FREQUENCY CONVERTER REOVIB MFS 368
More technology in the same design – that’s the motto of the new REOVIB MFS 368. The new devices consume up to 45% less power, which not only results in a better energy balance, but also lowers operating costs. This is achieved by compensating for reactive power. The lower energy consumption has a positive impact on the environment by reducing CO₂ emissions.
In addition, the frequency converters for vibratory feeding technology can boast a wide input voltage range from 99 V to 264 V with a constant output voltage of max. 205 V. They also offer the possibility of operating the vibratory feeder at a vibration frequency that is optimal for the material being conveyed, making it completely independent of the frequency of the supplying electrical network. This makes the device usable worldwide. Where several different feeders or magnets were previously required, now one REOVIB MFS 368 is sufficient.
In addition, it is possible to automatically determine the resonance frequency of the vibratory system and to implement control of the vibration amplitude to constant values using the ACC control method developed by REO. The advantage here is that the feeder automatically operates with optimum conveying performance regardless of the load or mechanical setting. This eliminates the need for complex adjustments to the feeder. With the new REOVIB MFS 368, you also always get optimum and maximum feeder performance, e.g. when the springs age, the mechanical load changes, or the voltage fluctuates.
The new converter has an integrated active mains filter, which saves additional costs for an external mains filter and reduces the power consumption, as well as an LCD display with plain text display. A temperature sensor for magnets can optionally be connected, which ensures that there are no failures due to defective magnets. This increases the operational reliability of the systems.
The devices can optionally be equipped with fieldbus interfaces and are optionally available as versions with UL/CSA certification. This enables uncomplicated use without effort and tests in systems in the USA and Canada.
The devices in the REOVIB MFS 368 series are available with a max. output current of 3 A, 6 A, 8 A and as IP20 control cabinet installation versions as well as IP54 housing versions. The IP54 housings can be supplied with various connection options:
- Input cable/output cable
- Input cable/output socket
- Completely pluggable with input connector, output socket and sensor and actuator connectors
Benefits
- Reduction of harmonics and thus of mains feedback
- Improved energy efficiency through reactive power compensation
- Active power is drawn from the supply network
- Output voltage 205 V with an input voltage range of 99 V to 264 V
- LCD display and plain text menu control
- Short circuit detection
- Output current limitation
- Optional connection for thermal contact for magnet temperature monitoring
- Additional 24 V valve output as an option
- Replaceable fieldbus interface
- The communication interface can be configured according to your needs
Typical applications
Input voltage | 99 V … 264 V |
Mains frequency | 50 / 60 Hz +/- 3 Hz |
Output voltage | 0…205 V |
Output current | max. 3 A / 6 A / 8 A |
Oscillation frequency | 20 … 140 Hz *¹ |
Set point specification | LCD Display, 0 … 10 V, 0 (4) … 20 mA |
Status signal | Relay changeover 24 V, 1A |
Brake signal | Relay changeover 24 V, 1A |
Ext. release | 24 V DC, switch |
Valve output | 24 V, 100 mA |
Sensor supply | 24 V DC |
Umin/ Umax setting | LCD Display |
Soft start | adjustable 0…60 sec. |
Soft stop | adjustable 0…60 sec. |
Fill level control/ Backflow circuit | PNP, 24 V DC |
Coarse/fine control | ✓ |
Amplitude control | ✓ |
Resonance frequency search | ✓ |
Resonance frequency control | ✓ |
Selectable clock mode | ✓ |
Sensor – Time Out control * | ✓ |
Mains voltage compensation | ✓ |
Short circuit detection | ✓ |
Output current limitation | ✓ |
Connection for thermal contact for magnetic temperature monitoring (option) | ✓ |
Additional 24 V valve output *¹ | ✓ |
Fieldbus interface | ProfiNet, EtherNet/IP, EtherCat, Profibus-DP, CAN-Bus, DeviceNet, |
Conformity | CE, RoHS, UL optional |
Protection classes | IP20, IP54 |
Ambient temperature | 0…40°C |
* For IP54
*¹ Other frequencies on request
All data and configurations can be found in our product data sheet.