REOLINE Plus AC-SG/A

REOLINE Laboratory Power Supplies (analog, separate windings) Description The laboratory variable transformers from the REOLINE Plus AC-SG/A series are equipped with an analog display, separate winding and continuously adjustable output voltage of 0..250 VAC. The absolute zero position results in a de-energized state at position 0. Benefits according to IEC/EN 61558-2-13 IEC/EN 61010-1 Mains connection cable 2 m long with Schuko plug Illuminated power switch with integrated thermal short-circuit protection Toroidal variable transformer with absolute zero position Isolation transformer with inrush current damping Analogue or digital voltmeter and ammeter at the output Earthing contact socket or safety labs at the output Short time overload possible Clean sine wave of the AC output voltage Easy connectivity Does not generate electromagnetic interference Modifications on request Typical applications Laboratory Test field Workshop and service Technical data Input voltage 230 V Output voltage 0 – 250 V Output current 3 x 0.6 – 8 A Output power 0.15 – 2.00 kVA Frequency 50 / 60 Hz Vector group li0 Max. ambient temperature + 40° Protection IP20 Produced in accordance with EN 61010-1 / VDE 0441 Part 1 Data sheet All data and configurations can be found in our product data sheet. Download datasheet
REOLINE Plus AC-S/D

REOLINE Laboratory Power Supplies (analogue, separate windings) Description The laboratory variable transformers from the REOLINE Plus AC-S/D series are equipped with a digital display, economy winding and continuously adjustable output voltage of 0..250 VAC. The absolute zero position results in a de-energized state at position 0. Benefits according to IEC/EN 61558-2-13 IEC/EN 61010-1 Mains connection cable 2 m long with Schuko plug Illuminated power switch with integrated thermal short-circuit protection Toroidal variable transformer with absolute zero position Analogue or digital voltmeter and ammeter at the output Earthing contact socket or safety labs at the output Short time overload possible Clean sine wave of the AC output voltage Easy connectivity Does not generate electromagnetic interference Modifications on request Inrush-current limitation optional Typical applications Laboratory Test field Workshop and service Technical data Input voltage 230 V Output voltage 0 – 250 V Output current 0,6 – 8 A Output power 0.15 – 2.00 kVA Frequency 50 / 60 Hz Vector group Spar Max. ambient temperature + 40° IP code IP40 Produced in accordance with EN 61010-1 / VDE 0441 Part 1 Data sheet All data and configurations can be found in our product data sheet. Download data sheet
REOLINE plus AC-S/A

REOLINE Laboratory Power Supplies (analog, auto-windings) Description The laboratory variable transformers from the REOLINE Plus AC-S/A series are equipped with an analog display, economy winding and continuously adjustable output voltage of 0..250 VAC. The absolute zero position results in a de-energized state at position 0. Benefits according to IEC/EN 61558-2-13 IEC/EN 61010-1 Mains connection cable 2 m long with Schuko plug Illuminated power switch with integrated thermal short-circuit protection Toroidal variable transformer with absolute zero position Analogue or digital voltmeter and ammeter at the output Earthing contact socket or safety labs at the output Short time overload possible Clean sine wave of the AC output voltage Easy connectivity Does not generate electromagnetic interference Modifications on request Inrush-current limitation optional Typical applications Laboratory Test field Workshop and service Technical data Input voltage 230 V Output voltage 0 – 250 V Output current 0,6 – 8 A Output power 0.15 – 2.00 kVA Frequency 50 / 60 Hz Vector group Spar Max. ambient temperature + 40° Protection IP20 Produced in accordance with EN 61010-1 / VDE 0441 Part 1 Data sheet All data and configurations can be found in our product data sheet. Download datasheet
Toroidal fixed transformer

Three-phase isolating transformer Description The three-phase toroidal fixed transformer is used for protective separation between both alternating voltage networks (through double or reinforced insulation, optimal: shielding winding). Benefits Use in contamination levels of up to PD3 Protection class IP 00 to IP 54 (with terminal boxes) Shock and vibration-resistant design (upon request) Use of high-quality cores for the minimisation of power loss Flexible adjustment to customer specifications (modified voltage ratio, voltage taps, performance values, high level of protection, temperature monitoring, additional windings and alternative switch groups possible) Optional: All materials upon request in accordance with REO UL-System E251513 Standards: EN 61558 Technical data Rated power 600 – 15.000 VA Input voltage 3 x 400; 3 x 230 V Output voltage 3 x 230; 3 x 400 V Rated current up to 3 x 22 A Frequency range 50 – 400 Hz Temperature class T40/E and T40/B % *Special voltages and higher powers on request Data sheet All data and configurations can be found in our product data sheet. Download datasheet Certifications
Housing And Interference Suppression Transformer

Attenuation of up to 90 dB is achieved with specially wound isolating transformers using segment winding technology, the low-capacitance design and an additional high-quality filter.
High current transformer

High-current transformers according to the current transformer principle Description High-current transformers enable the simple conversion of low primary currents into very high secondary currents. The compact and robust design is already equipped with reinforced insulation. This means that bare copper bars can be used as secondary windings, which are already safely insulated from the primary side without additional measures. The high-current transformers are fully pre-assembled on sturdy aluminum profiles and equipped with connection terminals in accordance with VGB 4. A connection for earthing the mounting rails is also provided. Due to parallel connection being possible, even higher output currents can be achieved.Typical areas of application are: Test devices for switchgears as well as lifting gates to examine the current and heating tests of the switching contacts. Benefits Partial sealing with large push-through opening for cable rails or busbars compact design Very low magnetic stray field Simply and quick assembly High electro-magnetic compatibility without additional components Pre-assembled on aluminium rails with clamps according to VBG 4 Standard: EN 61558 Technical data Rated power 815- 4000 VA Input voltage 230 V Output voltage 0,8 – 1,67 V Rated current max. 5000 A Frequency range 50 – 400 Hz Temperature class T40/E and T40/B *Special voltages and higher powers on request Data sheet You can find all data and configurations in our product data sheet. Download data sheet Certifications
Toroidal core transformer RFT-VV

Fully encapsulated toroidal transformer Description Fully encapsulated toroidal transformers in a special plastic housing combine all the advantages of the toroidal transformer. The shape of the housing can be adapted exactly to the application. The plastic housing offers optimum mechanical protection against moisture and dust and also provides better thermal conductivity, which leads to increased power density.The mounting is realized by means of a central screw and thus enables a short assembly time. Benefits Fully sealed in the plastic housing High efficiency Very low no-load losses No humming Low voltage drop Protection class IP 54 (for the fully sealed housing) Low magnetic stray field Optimal mechanical protection Protection against humidity and dust Even heat distribution Connects with wires, strands or clamps according to VBG 4 Standards: EN 61558; EN 60601 Technical data Rated power 10 – 6000 VA Input voltage 230 V Output voltage 24 – 690 V Rated current max. 50 A Frequency range 50 – 400 Hz Temperature class T40/E and T40/B *In addition to these standard series, we develop special solutions with special voltages and higher outputs according to your requirements. Please get in touch with us. Data sheet All data and configurations can be found in our product data sheet. Download datasheet Certifications
Toroidal Core Transformer RFT – MV

Toroidal fixed transformer with sealed centre hole as a mains, auto, safety or isolation transformer Description Toroidal transformers with central potting or foot potting offer the same advantages as open transformers, but also provide an excellent solution for mounting the transformer. This series of transformers eliminates the need for additional mounting hardware, replacing it with a central screw that also ensures quick assembly. A safe distance to the mounting surface is maintained. Benefits Integrated mounting plate with partial sealing No humming Low magnetic stray field Low voltage drop High efficiency Direct mounting option with just one screw Safe distance to the mounting surface Connection with wires or stranded wires Standards: EN 61558; EN 60601 Technical data Rated power 10 – 6000 VA Input voltage 230 V Output voltage 24 – 690 V Rated current max. 50 A Frequency range 50 – 400 Hz Temperature class T40/E and T40/B *In addition to these standard series, we develop special solutions with special voltages and higher outputs according to your requirements. Please get in touch with us. Data sheet All data and configurations can be found in our product data sheet. Download datasheet Certifications
Toroidal fixed transformer, open

The toroidal fixed transformer in open design as a mains, auto, safety or isolation transformer Description Toroidal transformers offer significant advantages over conventional transformers: Their design results in up to 50% less volume with low weight. Since the toroidal cores have almost no air gap, only a very low magnetic stray field is generated, and the transformers are almost hum-free. Between no-load and full load, the change in secondary voltage is many times smaller than with laminated core transformers. Benefits Adaptation of mains voltage to different output voltages No humming Low magnetic stray field Low voltage drop Minimum overall weight small dimensions Connection with free wire or stranded wires Mounting set available as an accessory Standards: EN 61558; EN 60601 Technical data Rated power 10 – 6000 VA Input voltage 230 V Output voltage 24 – 690 V Rated current max. 50 A Frequency range 50 – 400 Hz Temperature class T40/E and T40/B *In addition to these standard series, we develop special solutions with special voltages and higher outputs according to your requirements. Please get in touch with us. Data sheet All data and configurations can be found in our product data sheet. Download datasheet Certifications
Air reactor LD 210

Air reactor with aluminum/disc winding Description Air chokes are used when a particularly high linearity is required. By its relatively simple structure, they are not only compact, but also very stable. With our expertise, REO air chokes maintain their full functionality even under extreme conditions. With our expertise, the REO air reactors perform to the required standard, even in the most arduous conditions. REO Mix & Match principle With REO Mix & Match you can choose from a wide range of of options – combine the various options in order to always get the best product for your application. REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution. Optional Layer winding/Disc winding Aluminium, Copper or aluminium + copper Protections: Paint coating, protective coating, housing or REO Xtreme Cooling fan/unit Sensors: Switch NO / NC, PT100, NTC, PTC Advantages No saturation Wide range of material selection Special protective coating High linearity L (i) Very good mechanical strength No hysteresis Optimal weight by forced air cooling Directional air flow through GRP conduits Very efficient liquid cooling option (waveguide) Able to be universally applied. Technical data Frequency of the current: DC and AC Tolerances: + 10 / – 10 %, + 5 / – 5 % Taps: By default, no taps (available on request) Insulation: F or H Cooling method and cooling liquid according to IEC 60310: AN, AF or WF Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs Mounting: Suspended, vertical or horizontal Mechanical strength, mechanical simulation (FEM): EN 12663 Shock – and vibration stress: IEC 61373 Kat. 1 Kl. B Rated current: 100 – 700 A Type Inductance [mH] Cooling 3 m/s Cooling 5 m/s Cooling 8 m/s I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C LD 210/100/1 1 100 5 0,5 140 9,8 0,9 180 16,2 1,5 LD 210/200/1 1 200 20 1 280 39,2 2,1 35o 61,3 3,2 LD 210/400/1 1 400 80 3 500 125 4,6 600 180 6,6 LD 200/700/1 1 700 245 5,1 850 361,3 7,5 1000 500 10,4 LD 210/100/2 2 100 10 0,7 150 22,5 1,8 180 32,4 2,4 LD 210/200/2 2 200 40 1,6 300 90 3,6 380 144,4 5,8 LD 210/400/2 2 400 160 4,4 500 250 6,9 600 360 9,9 LD 210/700/2 2 700 490 8 850 722,5 11,7 1000 1000 16,2 LD 210/100/4 4 100 20 1,2 150 45 2,6 180 64,8 3,7 LD 210/200/4 4 200 80 2,5 300 180 5,7 380 288,8 9,1 LD 210/400/4 4 400 320 6,9 500 500 10,8 600 720 15,6 LD 210/700/4 4 700 980 12,4 850 1445 18,2 1000 2000 25,2 LD 210/100/8 8 100 40 1,7 150 90 3,9 180 129,6 5,6 LD 210/200/8 8 200 160 3,8 300 360 8,7 380 577,6 13,9 LD 210/400/8 8 400 640 10,7 500 1000 16,7 600 1440 24 LD 210/700/8 8 700 1960 19 850 2890 28 1000 4000 38,7 Dimensions in MM Type B [mm] H [mm] T [mm] Copper [kg] Weight [g] LD 210/100/1 300 300 130 5,06 14 LD 210/200/1 400 400 180 12,32 21 LD 210/400/1 500 500 190 23,54 49 LD 200/700/1 500 500 330 53,79 75 LD 210/100/2 350 350 180 7,81 13 LD 210/200/2 400 400 220 18,92 29 LD 210/400/2 450 450 280 34,1 51 LD 210/700/2 550 550 420 83,6 107 LD 210/100/4 350 350 230 12,21 17 LD 210/200/4 420 420 290 29,37 43 LD 210/400/4 500 500 370 53,79 77 LD 210/700/4 600 600 540 129,8 160 LD 210/100/8 350 350 270 18,26 27 LD 210/200/8 450 450 350 44,99 60 LD 210/400/8 550 550 430 82,83 110 LD 210/700/8 650 650 680 199,1 240